Skip to main content

ConceptSystem 59 Smoke & Heat Evacuation

Technical information

Performance

Energy

Thermal insulation - Uf
3.7 W/m²K
Thermal insulation - Uw
1.7 W/m²K
Uw Dependencies
Frame-vent: Ug 1.0W/m²K, warm edge spacer,@1.23x1.48m (86mm sight line), 24mm glass

Comfort

Air tightness
Class 1 (150Pa)
Water tightness
Class E750 (750Pa)
Wind load resistance
Class C2 (800Pa)
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Max. height of vent
2400 mm
Max. width of vent
1400 mm

Sightlines

Min. width T-profile
76 mm
Depth frame
50 mm
Depth Vent
59 mm

Glazing

Rebate height
25 mm
Min. glass thickness - frame/element
4 mm
Max. glass thickness - frame/element
35 mm